Ammonia Stripping & Rectification Q&A

Nov 17, 2026

Leave a message

1. What are the requirements for heavy metal content in the influent for ammonia removal via stripping and distillation?

It is recommended that the heavy metal content be ≤500 mg/L. If the heavy metal content exceeds 500 mg/L, pre-treatment measures can be added to ensure stable system operation.

 

2. What are the requirements for influent pH?

The influent pH shall be sufficient to convert ionic ammonium in wastewater into free ammonia. Ammonium salt solutions are buffer solutions, and the required pH varies with ammonia nitrogen species and ammonia nitrogen concentration.

 

3. Is there any relationship between the diameter and height of the ammonia removal tower and the influent ammonia nitrogen concentration?

The height of a stripping-rectification ammonia removal tower is generally 25~27 meters. The tower diameter and height are related not only to influent water quality and flow rate, but also to the concentration of recovered ammonia water, ammonia nitrogen index of tower bottom effluent and heavy metal index. The specific height shall be designed separately.

 

4. What does the reflux ratio control refer to in the ammonia removal system?

The reflux ratio is a core operating parameter of the rectification tower and a key control point to meet design requirements. The reflux ratio R = L/D, where L denotes the flow rate of ammonia water condensed at the tower top and returned to the tower, and D denotes the flow rate of ammonia water product withdrawn from the tower top.

 

5. What is the principle of the reflux ratio controller?

Essentially, the reflux ratio controller regulates the distribution ratio of two flow streams, which is realized by interlocked control of automatic valves and flow meters on the ammonia water pipeline.

A higher reflux ratio means more ammonia water returns to the tower, which promotes sufficient gas-liquid contact inside the tower, delivers better separation performance and higher purity of ammonia product. However, excessive reflux will increase energy consumption and reduce throughput. If the reflux ratio is too low, ammonia separation and purification will be inadequate. A large amount of water will be entrained with ammonia gas during overhead withdrawal, resulting in off-spec ammonia water concentration.

Therefore, reflux ratio control shall balance effluent indicators and steam energy consumption. Accurate calculation and design via Aspen simulation, together with commissioning by experienced site operators, are both indispensable. This prevents blind increase or decrease of the reflux ratio, which may lead to excessive energy consumption or non-compliant ammonia water concentration.

 

6. What is the working principle of the reboiler?

This specifically refers to a thermosiphon reboiler. The tower bottom liquid flows by gravity into the tube side of the reboiler driven by liquid level difference. Low-pressure saturated steam exchanges heat on the shell side and transfers heat to the wastewater. The wastewater is heated up to the bubble point temperature under the corresponding pressure and partially vaporizes inside the tubes to form a gas-liquid two-phase mixture. The inlet pipeline of the reboiler is full of liquid. The higher the vaporization ratio in the reboiler, the lower the density of the material in the outlet pipeline, and the greater the density difference between the two streams. Relying on this density difference between inlet and outlet pipelines, the tower bottom liquid is continuously "siphoned" into the reboiler and returns to the bottom of the rectification tower.

 

7. Will adding a reboiler to the ammonia removal system increase power consumption?

Generally, thermosiphon reboilers adopted in ammonia removal systems operate via natural circulation without pumps for continuous circulation. No circulating pump is required, so there will be no increase in power consumption.

 

8. How to select a reboiler if the wastewater contains high levels of suspended solids, heavy metals and scaling-prone substances?

In general, fouling formation in reboilers is related to water quality, fluid velocity, temperature, vaporization ratio, or a combination of these factors. When wastewater contains high concentrations of calcium, magnesium, nickel, cobalt, copper, zinc and other components, suspended solids such as calcium carbonate, calcium sulfate, magnesium hydroxide, metal oxides or hydroxides tend to precipitate during ammonia removal. Scaling inside heat exchange tubes is mainly suppressed by increasing flow velocity and reducing vaporization ratio. It is recommended to select a vertical thermosiphon reboiler or vertical forced-circulation reboiler, with a direct steam connection reserved. In addition, pre-treatment upstream of the ammonia removal system and cleaning frequency shall be taken into account during equipment selection.

 

9. Is the stripping-rectification ammonia removal tower operated under pressurized rectification or vacuum rectification?

The stripping-rectification ammonia removal tower manufactured by our company is an atmospheric rectification tower.

 

10. What are the pressures at the tower top and tower bottom?

The top of the stripping-rectification ammonia removal tower operates at atmospheric pressure (close to standard atmospheric pressure of 0.1 MPa), and the pressure at the tower bottom is 10~20 kPa.